Allerton are the premier off mains drainage company covering sales, servicing, commissioning and repairs of all types of septic tanks, sewage treatment plant, sewage pump stations and soakaways.

We will:

  • Save you money.
  • Maintain your compliance with regulators.
  • Help you protect the environment.
  • Extend the life of your system.
  • Delight you.

Contact us and we will be happy to make a site visit free of charge. Or you can simply discuss issues with any of our knowledgable staff in the office.

COVID-19 - Please note that while we are making site visits, we will not enter the house. We would, however, appreciate a bucket of warm water, soap, and a towel to wash our hands. 

 

Announcement: New Website Coming Soon!

Watch this space!

 

ALLERTON GROUND WATER TUBE (AGWT)

Contact our office to buy yours today!

£6 each*

Allerton Ground Water Tube Sketch Plan

The ideal solution for measuring your soakaway (drainage field) water levels.

Allerton Ground Water Tube

Learn more here.

*2 for £10, 3 for £14 (all prices include UK postage but exclude VAT)

Excellent service and attitude from staff

Mr B (Sewage treatment plant service and repair)

Many thanks for your kind and cheerful service

Mrs Potts (Sewage Treatment Plant Service)

A fantastic experience from quote to completion & considerably cheaper than competition

Mr Stokes, Surfleet (ConSept - New Installation)

 

We do specialised pump stations for awkward situations!

Need something very small, very shallow, or narrow? Need the inlet at the top? We can do that for you! Whatever your unique specification requirements, Allerton can accommodate!

 

We are now available for drain unblocking. If you have a clogged drain, be sure to contact Allerton
 
 

The Allerton High Capacity Storm Water Pump Station

The Allerton High Capacity Storm Water pump station is recommended for applications where gravity flow is not available.

Why use our Storm Water Pump Station?

  • The pump chambers are manufactured from high quality glass reinforced plastic and in accordance with our BS EN ISO9001:2000 quality management system.
  • Single phaseand three phase pumps available.
  • The Allerton High Capacity Storm Water Pump Station is delivered complete with the >pipework and valves pre-assembled in the tank, ready for immediate installation into the ground.
  • High-level alarm included.
  • 1 year warranty on all working parts.
  • Wide range of diameters and depths of tanks available to satisfy the storage requirements in part H of the Building Regs.
  • Custom made storm water pump stations available upon request.
  • Pump Station Servicing and Maintenance, Installation and Commissioning service available by our highly trained engineers.

 

How our Storm Water Pump Station works

See illustration below.¹

Allerton dual dirty water and storm water pumping station illustration

  1. Galvanised Access Cover
  2. GRP Tank
  3. Inlet Pipe
  4. High Level Alarm Float
  5. Control Panel
  6. Quick Release Coupling
  7. Isolation Valve
  8. Non Return Valve
  9. Submerged Pump with Integral Float

As the level of the liquid rises in the chamber the integral float on the pump is activated, the pump starts and pumps the liquid out of the chamber until the pump float drops and the pump turns off.

The level of the liquid will again rise and the above sequence is repeated.

If the pump fails to pump, the liquid level will rise to activate the high level float and the high-level alarm light will be illuminated.

¹ Allerton High Capacity Storm Water Pump Station illustration is not drawn to scale.

Dimensions (mm)

Allerton storm water pump station diagram
 
STORAGE          
CAPACITY / P/E* 5 12 20 27 44
(A) INLET 1000 1000 500 1000 500
(B) BELOW INLET 1400 2000 3000 2000 3000
(C) HEIGHT 2400 3000 3500 3000 3500
(D) DIAMETER 1000 1200 1200 1800 1800
(E) OUTLET 350 350 350 350 350

*Population Equivalent

 

 

Download our High Capacity Storm Water Pump Station specification

Adobe PDF


 

Alternative pumping stations

Servicing and maintenance

Allerton reserves the right to alter the Allerton High Capacity Stormwater Pump Station specifications and dimensions without notice.

 

ukas-logo

The Allerton Dual Dirty Water Pump Station

The Allerton Dual Dirty Water Pump Station is recommended for applications where gravity flow is not available. Pumping treated effluent from septic tanks, treatment plants, stormwater, surface water and drainage. Contact Allerton for sizing information.


Why use our Dual Dirty Water Pump Station?

  • The pump chambers are manufactured from high quality glass reinforced plastic and in accordance with our BS EN ISO9001:2000 quality management system.
  • Single phase and three phase pumps available.
  • The Allerton Dual Dirty Water Pumping Station is delivered complete with the pipework and valves pre-assembled in the tank, ready for immediate installation into the ground.
  • High-level alarm included.
  • 1 year warranty on all working parts.
  • Wide range of diameters and depths of tanks available to satisfy the storage requirements in part H of the Building Regs.
  • Low maintenance costs, servicing once a year.
  • Custom made dual dirty water pumping stations available upon request.
  • Pump Station Servicing and Maintenance, Installation and Commissioning service available by our highly trained engineers.

How our Dual Dirty Water Pump Station works

See illustration below.¹

Allerton dual dirty water pump station illustration, Lincolnshire

  1. Galvanised Access Cover
  2. GRP Tank
  3. Inlet Pipe
  4. High Level Alarm Float
  5. Control Panel
  6. Quick Release Coupling
  7. Isolation Valve
  8. Non Return Valve
  9. Submerged Pump with Integral Float

 

As the level of the liquid rises in the chamber the integral floats are factory set at the same level, both pumps start and pump the liquid out of the chamber until the pump floats drop and the pumps turn off. 

The level of the liquid will again rise and the above sequence is repeated. As both pumps are activated each time this ensures equal wear to both pumps.

If the pump fails to pump, the liquid level will rise to activate the high level float and the high level alarm light will be illuminated.

¹ Allerton Dual Dirty Water Pump Station illustration is not drawn to scale.

 

Dimensions (mm)

Allerton dual dirty water pumping station diagram

STORAGE            
CAPACITY / P/E* 0 5 12 20 27 44
(A) INLET 500 1000 1000 500  1000  500
(B) BELOW INLET 900 1400 2000 3000 2000  3000 
(C) HEIGHT 1400 2400 3000 3500 3000  3500 
(D) DIAMETER 1000 1000 1200 1200  1800 1800 
(E) OUTLET 350 350 350 350  350 350 
*Population Equivalent

Download our Dual Dirty Water Pump Station specification

Adobe pdf


Alternative Pumping Stations

Servicing and Maintenance

 

Allerton reserves the right to alter the Dual Dirty Water Pump Station specifications and dimensions without notice. 

 

 ukas-logo ccas registered

 
 

Allerton Dirty Water Pump Station

 

This is a general purpose pump station capable of pumping spring water through to septic tank water.

 

What comes with the Allerton Dirty Water Pump Station?

  • The pump chambers are manufactured from high quality glass reinforced plastic and in accordance with our BS EN ISO9001:2000 quality management system.
  • Single phase and three phase pumps available.
  • The Allerton Dirty Water Pump Station is delivered complete with the pipework and valves pre-assembled in the tank, ready for immediate installation into the ground.
  • High-level alarm included.
  • Low maintenance costs, servicing once a year.
  • Custom made Dirty Water Pump Stations available on request
  • Pump Station Servicing and Maintenance, Installation and Commissioning service available by our highly trained engineers.

 

How does the Dirty Water Pump Station work?

See illustration below.¹

As the level of the liquid rises in the chamber the integral float on the pump is activated, the pump starts and pumps the liquid out of the chamber until the pump float drops and the pump turns off.

The level of the liquid will again rise and the above sequence is repeated.

If the pump fails to pump, the liquid level will rise to activate the high level float and the high level beacon will be illuminated.

¹External pump chamber illustration is not drawn to scale.

 

Dimensions (mm)

Allerton dirty water pumping station diagram
 
 
STORAGE            
CAPACITY / P/E* 0 0 0 5 5 5
(A) INLET 500 1000 1500 500 1000 1500
(B) BELOW INLET 900 900 900 1400 1400 1400
(C) HEIGHT 1400 1900 2400 1900 2400 2900
(D) DIAMETER 600 600 600 1000 1000 1000
(E) OUTLET 350 350 350 350 350 350
 *Population Equivalent
 
 
 

Download our Dirty Water Pump Station specification

Adobe PDF


 

View our range of sewage treatment plants

 

Alternative Pump Stations

 

Servicing and Maintenance

 

Allerton reserves the right to alter the Allerton Dirty Water Pumping Station specifications and dimensions without notice.

 

 

ukas-logo ccas registered

 
 

The Allerton High Specification Dual Raw Sewage Pump Station

The Allerton High Specification Dual Raw Sewage Pump Station is recommended where gravity flow is not available to the main sewer and for one or more properties. Contact Allerton for sizing information.

 

Why use our High Specification Pump Station?

  • The pump chambers are manufactured from high quality Glass Reinforced Plastic and in accordance with our BS EN ISO9001:2000 quality management system.
  • Fully automatic autochangeover control system to ensure equal wear and tear on each pump.
  • The Allerton Raw Sewage Pump Station is delivered complete with the pipework, valves and guide rails pre-assembled in the tank, ready for immediate installation into the ground.
  • Wide range of diameters and depths of tanks available to satisfy the storage requirements in part H of the Building Regs.
  • Low maintenance costs, servicing once a year.
  • 1 year warranty on all working parts.
  • Custom made sewage pump stations available upon request.
  • Pump Station Servicing and Maintenance, Installation and Commissioning service available by our highlytrained engineers.

 

How our High Specification Pump Station works

See illustration below.¹

Allerton high specification pump station illustration, Lincolnshire
  1. Galvanised Access Cover
  2. GRP Tank
  3. Inlet Pipe
  4. Level Float Controls
  5. Control Panel
  6. Galvanised Guide Rail
  7. Isolation Valve
  8. Non Return Valve
  9. Submersible Pumps

As the level of the liquid rises in the chamber the first two level floats, the stop and duty start floats are activated and the duty pump starts and pumps the liquid out of the chamber until the stop float drops and turns the pump off. The level of the liquid will again rise and due to the autochangeover control system the other pump will start. This ensures that the two pumps do an equal amount of work.

If the liquid level reaches the height of the second level float and the pump fails to pump, the level of liquid will continue to rise until the third float is activated and calls the standby pump to start. This pump will then start and pump until the stop float drops. If both pumps fail to pump, the liquid level will rise to the fourth float and the high level alarm will be activated.

¹ Allerton High Spec Dual Raw Sewage Pump Station illustration is not drawn to scale.

 

Dimensions (mm)

allerton high specification pump station diagram
 
STORAGE            
CAPACITY / P/E* 0 5 12

 20

27

44

(A) INLET 500 1000 1000  500 1000 500
(B) BELOW INLET 900 1400  2000  3000 2000 3000
(C) HEIGHT 1400 2400 3000  3500  3000 3500
(D) DIAMETER 1000 1000  1200 1200  1800 1800
(E) OUTLET 350 350 350   350 350 350
*Population Equivalent
 

Download our High Specification Pump Station Specification

Adobe Pdf

 


Alternative pumping stations

 

Servicing and Maintenance

Allerton reserves the right to alter the Allerton High Spec Dual Raw Sewage Pumping Station specifications and dimensions without notice.

 

 

ukas-logo ccas registered

The Allerton Dual Raw Sewage Pumping Station

The Allerton Dual Raw Sewage Pumping Station is recommended for applications where gravity flow is not available to the main sewer and for one or more properties. Contact Allerton for sizing information.


Why use our Dual Raw Sewage Pumping Station?

  • The pump chambers are manufactured from high quality glass reinforced plastic and in accordance with our BS EN ISO9001:2000 quality management system.
  • Single phase and three phase pumps available.
  • High-level alarm included.
  • The Allerton Dual Raw Sewage Pumping Station is delivered complete with the pipework and valves pre-assembled in the tank, ready for immediate installation into the ground.
  • Wide range of diameters and depths of tanks available to satisfy the storage requirements in part H of the Building Regs.
  • 1 year warranty on all working parts.
  • Custom made sewage pumping stations available upon request.
  • Pump Station Servicing and Maintenance, Installation and Commissioning service available by our highly trained engineers.
  • Low maintenance costs, servicing once a year.

How our Dual Sewage Pumping Station works

See illustration below.¹

Allerton dual sewage pumping station illustration, Lincolnshire sewage treatment

  1. Galvanised Access Cover
  2. GRP Tank
  3. Inlet Pipe
  4. High Level Alarm Float
  5. Control Panel
  6. Quick Release Coupling
  7. Isolation Valve
  8. Non Return Valve
  9. Submerged Pump with Integral Float

 

As the level of the liquid rises in the chamber the integral floats on the pumps are activated and, as the floats are factory set at the same level, both pumps start and pump the liquid out of the chamber until the pump floats drop and the pumps turn off.

The level of the liquid will again rise and the above sequence is repeated. As both pumps are activated each time this ensures equal wear to both pumps.

If both pumps fail to pump, the liquid level will rise to activate the high level float and the high level alarm light will be illuminated.

¹ Allerton Dual Raw Sewage Pumping Station illustration is not drawn to scale.

 

Dimensions (mm)

Allerton dual sewage pumping station diagram
 
 
STORAGE            
CAPACITY / P/E* 0 5 12 20 27 44
(A) INLET 500 1000 1000 500 1000 500
(B) BELOW INLET 900 1400 2000 3000 2000 3000
(C) HEIGHT 1400 2400 3000 3500 3000 3500
(D) DIAMETER 1000 1000 1200 1200 1800 1800
(E) OUTLET 350 350 350 350 350 350
*Population Equivalent

Download our Dual Raw Sewage Pumping Station specification

 Adobe Pdf Dual Sewage Pumping Station

 


Alternative pumping stations

 

Servicing and Maintenance

 

Allerton reserves the right to alter the Allerton Dual Raw Sewage Pump Station specifications and dimensions without notice.

 

ukas-logo ccas registered