The Allerton Raw Sewage Pump StationThe Allerton Raw Sewage Pump Station is recommended for applications where gravity flow is not available to the main sewer and for one or more properties. Contact Allerton for sizing information. Why use our Raw Sewage Pump Station?
How our Sewage Pump Station worksSee illustration below.¹
As the level of the liquid rises in the chamber the integral float on the pump is activated, the pump starts and pumps the liquid out of the chamber until the pump float drops and the pump turns off. The level of the liquid will again rise and the above sequence is repeated. If the pump fails to pump, the liquid level will rise to activate the high level float and the high level alarm light will be illuminated. For applications involving more than one dwelling we would recommend our dual raw sewage pump station. ¹ Allerton Raw Sewage Pumping Station illustration is not drawn to scale. Dimensions (mm) |
STORAGE | ||||||
CAPACITY / P/E* | 0 | 0 | 0 | 5 | 5 | 5 |
(A) INLET | 500 | 1000 | 1500 | 500 | 1000 | 1500 |
(B) BELOW INLET | 900 | 900 | 900 | 1400 | 1400 | 1400 |
(C) HEIGHT | 1400 | 1900 | 2400 | 1900 | 2400 | 2900 |
(D) DIAMETER | 600 | 600 | 600 | 1000 | 1000 | 1000 |
(E) OUTLET | 350 | 350 | 350 | 350 | 350 | 350 |
*Population Equivalent |
Download our Sewage Pump Station specificationAlternative pumping stations
Servicing and MaintenanceAllerton reserves the right to alter the Allerton Raw Sewage Pump Station specifications and dimensions without notice.
|